RENTAL RATES ($)
MFG & MODEL
INSTRUMENT
DESCRIPTION
MONTHLY
(28 days)
WEEKLY
(7 Days)

RATEMETERS / SCALERS / ION CHAMBERS / TRAY COUNTERS
Bicron/Thermo MicroRem Meter
Tissue Equivalent Exposure Meter
These instruments give tissue-equivalent photon response for X-ray and gamma radiation from environmental levels of 0 to 20 µrem/h (0 to 0.2 µSv/h) full scale up to normal survey levels of 200 mrem/h (2 mSv/h) full scale.
250
100
Ratemeter
General survey meter used with probes to measure rates/counts. readouts for alpha and beta counts. Adjustable count time.
100
50
micro-R Survey Meter NORM Meter
Ratemeter with NaI 1"x1" probe. Used for gamma ray exposure rates. Often referred to as a NORM meter. (Calibrated to Cs-137)
125
75
Ratemeter
General survey meter used with probes to measure rates/counts. Adjustable HV and threshold.
100
50
Ludlum 9 Ion Chamber General purpose survey meter. Exposure rate measurements.
(0 - 5000 mR/hr)
125
75
micro-R Survey Meter
Gamma ray exposure rates. (0 - 5mR/hr)
(Calibrated to Cs-137 or Ra-226)
100
50
Alarm Ratemeter
Used with GM detector at frisking station.
100
50
Scaler (120v AC
powered)
Used for gross sample counting. Digital readout. Adjustable count time. Typically used with 43-10.
150
50
Scaler (120v AC or 4 D-cell Battery)
Used for gross sample counting. Digital readout. Adjustable count time and threshold. Typically used with 43-10.
200
75
Digital Scaler/Ratemeter
General survey meter used with probes to measure rates/counts. Adjustable count time, HV, and window. Single Channel Analyzer.
225
75
Ludlum 2221 (RS232)
Digital Scaler/Ratemeter
Same as 2221 with RS232 output. 1 & 2 second data dump available.
250
85
Digital Alpha/Beta
Scaler/Ratemeter
Discriminates between alpha and beta when used with phoswhich detector. Typically set up with proportional or phoswhich detector.
150
75
Digital Scaler/Ratemeter
General survey meter used with probes to measure rates/counts.
150
75
Digital Alpha/Beta
Data Logger
Discriminates between alpha and beta when used with phoswhich detector. Typically set up with proportional or phoswhich detector. Capable of logging up to 550 individual data points.
200
100

Alpha/Beta Scaler &
Phoswhich Tray Counter

Scaler paired with alpha/beta tray counter. Separate LED
275
125

RADIATION MEASUREMENT DETECTORS
Alpha Probe
ZnS alpha scintillator (83 cm2 active area) used for surface contamination monitoring.
100
50
Alpha Probe
ZnS alpha scintillator (76 cm2 active area) used for surface contamination monitoring.
55
40
Alpha Tray Counter
ZnS alpha scintillator. Tray counter for wipe and air samples. Typically used with model 1000, 2000, or 2221.
75
40
Large Area Alpha/Beta Gas Proportional Probe
Large area gas proportional (582 cm2 active area) used for surface contamination monitoring. Must be charged with P-10 counting gas.
350
175
Alpha/Beta Gas Proportional Probe
Gas proportional (126 cm2 active area) used for surface contamination monitoring. Must be charged with P-10 counting gas.
80
50
Alpha/Beta Phoswhich Probe
ZnS alpha scintillator with thick plastic beta scintillation material (126 cm2 active area) used for surface contamination monitoring.
125
75
Alpha Probe
ZnS alpha scintillator (126 cm2 active area) used for surface contamination monitoring.
90
75
Alpha/Beta Phoswhich Probe
ZnS alpha scintillator with thick plastic beta scintillation material (100 cm2 active area) used for surface contamination monitoring.
150
100
Beta Probe
Scintillator (11.6 cm2 open and active area) used for beta detection.
75
40
Low Energy Gamma Probe
1"x1mm NaI gamma scintillator probe for low energy gamma (I-125) and X-ray surveys.
75
40
Pancake G-M Probe
Aluminum housed G-M tube (15 cm2 active area) used for alpha, beta/gamma survey.
40
30
Gamma Probe
NaI 2"x2" probe with gamma scintillator used for high energy gamma surveys. High sensitivity gamma survey when used with polyshield as collimator.
75
40
Ludlum 44-17 Low Energy Gamma Probe 2" x 2mm NaI gamma scintialltor probe for low energy gamma (I-125) and X-ray surveys.
125
75
Gamma Probe
NaI 3"x3" probe with gamma scintillator used for high energy gamma surveys. High sensitivity gamma survey when used with polyshield as collimator.
500
300
Shielded Pancake G-M Probe
Lead shielded G-M tube (15 cm2 active area) used for alpha, beta-gamma survey. For use in high gamma shine areas.
50
35
Beta Probe
Plastic beta scintillator (126 cm2 active area) used for surface contamination monitoring.
95
75
Ludlum 182 Radon Flask Counter Lucas Cell Counting
200
100
Ludlum 218 Radon Flask Counter Large flask counter (5 in. dia.) Great for gross alpha soil sample counting. Contact Chuck Farr or Ken Baker at ERG for discussion on how to set up a gross alpha field lab using the Model 218.
350
200
Floor Monitor Cart, Gas Proportional Probe, and Ludlum 2221 or 2360 Detector
Gas proportional (582cm2 active area) used for floor / surface contamination monitoring. Must be charged with P-10 counting gas. The price includes cart, meter, probe and regulator. User must provide P-10 gas cylinder.
700
350
Eberline HP210L
Shielded Pancake G-M Probe
Lead shielded G-M tube (15 cm2 active area) used for alpha, beta-gamma survey. For use in high gamma shine areas.
50
35
Alpha Spectra FIDLER
Low Energy Photon Probe
Beryllium window thin NaI scintillator for the detection of low energy photons. (F)ield (I)nstrument for (D)etecting (L)ow (E)nergy (R)adiation.
800
300


INDUSTRIAL HYGIENE EQUIPMENT & SUPPLIES

MIE Personal DataRAM pDR-1000AN Aerosol Monitor Hand-Held and fixed-point, real-time aerosol monitor and data logger

600

200
Photovac 2020 PID Photoionization Detector The Photovac 2020 PID is ideal for the fast detection of Volatile Organic Compounds (VOCs). Weighing under 2 lbs., the Photovac 2020 is light, yet rugged. Samples are drawn in through the internal pump and results are displayed within seconds on the large, easy-to-read backlit LCD display.
600
200

MSA Passport Personal Alarm

LEL, CO, O2 H2S Monitor Allows you to continuously monitor up to five gases simultaneously in a single compact unit. Weighing only 30 ounces, the Passport Personal Alarm can be hand held, clipped to your belt, or positioned in a stationary area.
600
200
Extech Model 407330 Digital Sound Meter NIST Traceable Digital Noise Meter. 40 to 130dB measuring range. Record Max/Min values over time
75
50
Lapel Air Sampler
For personal air sampling. Sampling rate of up to 3 liters per minute. Includes charger, and 37 mm filter holder. Cyclone particle separator available.
200
120
MiniBUCK M-5 Primary Flow Lapel Calibrator NIST traceable digital calibrator for MSA Escort ELF Air Sampler.
200
100
Eberline RAS-1
Intermediate Volume Air Sampler
For air quality measurements. Sampling rate of up to 80 liters per minute. Unit comes with 47 mm filter holder.
125
100
37mm Air filter
Gelman Type A/E 37mm Glass Fiber Filter. Box of 100.
50
47mm Air filter
Gelman Type A/E 47mm Glass Fiber Filter. Box of 100.
50
37mm Air filter cartridge
Plastic cartridge to hold 37mm air filter. Package of 10.
50
47mm Planchetts
47mm aluminum planchetts. Package of 100.
25

RADIOACTIVE SOURCES / OTHER EQUIPMENT / SUPPLIES
Trimble Pro XRS & TSCe GPS Survey System GPS data collection and data maintenance system that provides real-time submeter accuracy. Incorporates a 12-channel, differential correction service antenna, coast guard beacon antenna, and DOD GPS satellite antenna in one housing
Model 44-10
3000
750
FIDLER
3400
850
RadMap
Ultrasonic Automated Survey System
Ultrasonic survey system that automatically records ratemeter/scaler output and associated X, Y, Z position. For full description see ERG Indoor Survey Systems.
3000
n/a
Eberline Depleted U
Electroplated Source
Exempt quantity Depleted Uranium source.
50
25
Eberline Th-230
Electroplated Source
Exempt quantity Thorium-230 Alpha source.
50
25
Eberline Sr/Y-90
Electroplated Source
Exempt quantity Strontium-90 / Yttrium-90 source.
50
25
The Source Cs-137
Button Source
Exempt quantity Cesium-137 source.
50
25
The Source Tc-99
Electroplated Source
Exempt quantity Technetium-99 Beta source.
50
25
Canberra MCA
Multi-Channel Analyzer
Gamma-ray MCA with NaI 3"x3" detector, 386 computer, and appropriate Canberra software.
700
n/a
EG&G Ortec MCA
Multi-Channel Analyzer
(Field portable)
Micro NOMAD or DigiDART field portable gamma-ray MCA with NaI 2"x2" or 3"x3" detector and appropriate EG&G ORTEC software.
800
350
Polyshield Lead Collimator
1/2" thick lead shield used with Ludlum Model 44-10 for high sensitivity gamma survey.
50
20
Removable contamination smears 1 3/4" dia. cloth smears premounted on folders. Box of 250.
25

OTHER SERVICES AVAILABLE
Health Physics Consulting
Decommissioning Support
Remediation Plans
GPS - Based Radiological Surveys
HP Technicians
GIS Support (ArcView)
Radon Flux Measurements - (EPA Method 115)
For quotes on other services contact Kenneth R. Baker, PhD at (505)-298-4224

 

8809 Washington St. NE Suite 150
Albuquerque, NM 87113
Tel: (505) 298-4224 
Fax: (505) 797-1404

©2003, 2005, 2007 Environmental Restoration Group, Inc. All Rights Reserved.

Print this page