| Radiation Measurement Detectors |
| MFG & MODEL |
INSTRUMENT |
DESCRIPTION |
WEEKLY RATE |
MONTHLY RATE |
| Ludlum 43-1 |
Alpha Probe |
ZnS alpha scintillator (83 cm2 active area) used for surface contamination monitoring. |
50 |
100 |
| Ludlum 43-5 |
Alpha Probe |
ZnS alpha scintillator (76 cm2 active area) used for surface contamination monitoring. |
40 |
55 |
| Ludlum 43-10 |
Alpha Tray Counter |
ZnS alpha scintillator. Tray counter for wipe and air samples. Typically used with model 1000, 2000, or 2221. |
40 |
75 |
| Ludlum 43-37 |
Large Area Alpha/Beta Gas Proportional Probe |
Large area gas proportional (582 cm2 active area) used for surface contamination monitoring. Must be charged with P-10 counting gas. |
175 |
350 |
| Ludlum 43-68 |
Alpha/Beta Gas Proportional Probe |
Gas proportional (126 cm2 active area) used for surface contamination monitoring. Must be charged with P-10 counting gas. |
50 |
80 |
| Ludlum 43-89 |
Alpha/Beta Phoswhich Probe |
ZnS alpha scintillator with thick plastic beta scintillation material (126 cm2 active area) used for surface contamination monitoring. |
75 |
125 |
| Ludlum 43-90 |
Alpha Probe |
ZnS alpha scintillator (126 cm2 active area) used for surface contamination monitoring. |
75 |
90 |
| Ludlum 43-93 |
Alpha/Beta Phoswhich Probe |
ZnS alpha scintillator with thick plastic beta scintillation material (100 cm2 active area) used for surface contamination monitoring. |
100 |
150 |
| Ludlum 44-94 |
Alpha/Beta/Gamma Detector |
4 GM pancake detector. |
50 |
100 |
| Ludlum 44-1 |
Beta Probe |
Scintillator (11.6 cm2 open and active area) used for beta detection. |
40 |
75 |
| Ludlum 44-3 |
Low Energy Gamma Probe |
1"x1mm NaI gamma scintillator probe for low energy gamma (I-125) and X-ray surveys. |
40 |
75 |
| Ludlum 44-9 |
Pancake G-M Probe |
Aluminum housed G-M tube (15 cm2 active area) used for alpha, beta/gamma survey. |
30 |
40 |
| Ludlum 44-10 |
Gamma Probe |
NaI 2"x2" probe with gamma scintillator used for high energy gamma surveys. High sensitivity gamma survey when used with polyshield as collimator. |
40 |
75 |
| Ludlum 44-17 |
Low Energy Gamma Probe |
2" x 2mm NaI gamma scintialltor probe for low energy gamma (I-125) and X-ray surveys. |
40 |
75 |
| Ludlum 44-20 |
Gamma Probe |
NaI 3"x3" probe with gamma scintillator used for high energy gamma surveys. High sensitivity gamma survey when used with polyshield as collimator. |
300 |
500 |
| Ludlum 44-40 |
Shielded Pancake G-M Probe |
Lead shielded G-M tube (15 cm2 active area) used for alpha, beta-gamma survey. For use in high gamma shine areas. |
35 |
50 |
| Ludlum 44-62 |
Gamma Probe |
NaI 0.5" diameter x 1" thick scintillator used for wide-energy gamma detection |
40 |
75 |
| Ludlum 44-116 |
Beta Probe |
Plastic beta scintillator (126 cm2 active area) used for surface contamination monitoring. |
75 |
95 |
| Ludlum 182 |
Radon Flask Counter |
Lucas Cell Counting |
100 |
200 |
| Ludlum 218 |
Radon Flask Counter |
Large flask counter (5 in. dia.) Great for gross alpha soil sample counting. Contact Chuck Farr or Ken Baker at ERG for discussion on how to set up a gross alpha field lab using the Model 218. |
200 |
350 |
| Ludlum 239-1F |
Floor Monitor Cart, Gas Proportional Probe, and Ludlum 2221 or 2360 Detector |
Gas proportional (582cm2 active area) used for floor / surface contamination monitoring. Must be charged with P-10 counting gas. The price includes cart, meter, probe and regulator. User must provide P-10 gas cylinder. |
350 |
700 |
| Eberline HP210L |
Shielded Pancake G-M Probe |
Lead shielded G-M tube (15 cm2 active area) used for alpha, beta-gamma survey. For use in high gamma shine areas. |
35 |
50 |
| Alpha Spectra FIDLER |
Low Energy Photon Probe |
Beryllium window thin NaI scintillator for the detection of low energy photons. (F)ield (I)nstrument for (D)etecting (L)ow (E)nergy (R)adiation. |
300 |
800 |
| Ortec High-Purity Germanium (HPGe) Gamma Spectrometer |
Germanium Detector |
System consists of everything: Ortec 40+% efficiency detector, Ortec X-Cooler II Mechanical Cooler with cold head assembly (no need for liquid nitrogen), DigiDART MCA, Desktop computer with GammaVision-32 application and an ERG system housing with lead shield. Call to discuss weekly price. |
|
10,000 |