| Ratemeters, Scalers,
Ion Chambers, & Tray Counters |
Radiation Measurement
Detectors |
Radioactive Sources,
Other Equipment, & Supplies |
Industrial Hygiene Equipment |
![]() |
![]() |
![]() |
![]() |
|
Prices Effective June 1, 2008
|
|
RENTAL RATES ($)
|
||||||||
|
MFG & MODEL
|
INSTRUMENT
|
DESCRIPTION
|
MONTHLY
(28 days) |
WEEKLY
(7 Days) |
||||
| Bicron/Thermo MicroRem Meter |
Tissue Equivalent Exposure Meter
|
These instruments give tissue-equivalent photon response for X-ray and gamma radiation from environmental levels of 0 to 20 µrem/h (0 to 0.2 µSv/h) full scale up to normal survey levels of 200 mrem/h (2 mSv/h) full scale. |
250
|
100
|
||||
|
Ratemeter
|
General survey meter used with probes
to measure rates/counts. readouts for alpha and beta counts. Adjustable count
time.
|
100
|
50
|
|||||
|
micro-R Survey Meter NORM Meter
|
Ratemeter with NaI 1"x1" probe. Used for gamma ray
exposure rates. Often referred to as a NORM meter. (Calibrated to Cs-137)
|
125
|
75
|
|||||
|
Ratemeter
|
General survey meter used with probes to measure
rates/counts. Adjustable HV and threshold.
|
100
|
50
|
|||||
| Ludlum 9 | Ion Chamber | General purpose survey meter. Exposure rate
measurements.
(0 - 5000 mR/hr) |
125
|
75
|
||||
|
micro-R Survey Meter
|
Gamma ray exposure rates. (0 - 5mR/hr)
(Calibrated to Cs-137 or Ra-226) |
100
|
50
|
|||||
|
Alarm Ratemeter
|
Used with GM detector at frisking station.
|
100
|
50
|
|||||
|
Scaler (120v AC
powered) |
Used for gross sample counting. Digital readout.
Adjustable count time. Typically used with 43-10.
|
150
|
50
|
|||||
|
Scaler (120v AC or 4 D-cell Battery)
|
Used for gross sample counting. Digital readout.
Adjustable count time and threshold. Typically used with 43-10.
|
200
|
75
|
|||||
|
Digital Scaler/Ratemeter
|
General survey meter used
with probes to measure rates/counts. Adjustable count time,
HV, and window. Single Channel Analyzer. RS-232 option upon
request.
|
225
|
75
|
|||||
|
Digital Alpha/Beta
Scaler/Ratemeter |
Discriminates between alpha and beta when used with
phoswhich detector. Typically set up with proportional or phoswhich detector.
|
150
|
75
|
|||||
|
Digital Scaler/Ratemeter
|
General survey meter used with probes to measure
rates/counts.
|
150
|
75
|
|||||
|
Digital Alpha/Beta
Data Logger |
Discriminates between alpha and beta when used with
phoswhich detector. Typically set up with proportional or phoswhich detector.
Capable of logging up to 550 individual data points.
|
200
|
100
|
|||||
|
Alpha/Beta Scaler & |
Scaler paired with alpha/beta tray counter. Separate
LED for both alpha and beta channels.
|
275
|
125
|
|||||
|
Alpha Probe
|
ZnS alpha scintillator (83 cm2 active area) used for
surface contamination monitoring.
|
100
|
50
|
|||||
|
Alpha Probe
|
ZnS alpha scintillator (76 cm2 active area) used for
surface contamination monitoring.
|
55
|
40
|
|||||
|
Alpha Tray Counter
|
ZnS alpha scintillator. Tray counter for wipe and air
samples. Typically used with model 1000, 2000, or 2221.
|
75
|
40
|
|||||
|
Large Area Alpha/Beta Gas Proportional Probe
|
Large area gas proportional (582 cm2 active area) used
for surface contamination monitoring. Must be charged with P-10 counting gas.
|
350
|
175
|
|||||
|
Alpha/Beta Gas Proportional Probe
|
Gas proportional (126 cm2 active area) used for
surface contamination monitoring. Must be charged with P-10 counting gas.
|
80
|
50
|
|||||
|
Alpha/Beta Phoswhich Probe
|
ZnS alpha scintillator with thick plastic beta
scintillation material (126 cm2 active area) used for surface contamination
monitoring.
|
125
|
75
|
|||||
|
Alpha Probe
|
ZnS alpha scintillator (126 cm2 active area) used for
surface contamination monitoring.
|
90
|
75
|
|||||
|
Alpha/Beta Phoswhich Probe
|
ZnS alpha scintillator with thick plastic beta
scintillation material (100 cm2 active area) used for surface contamination
monitoring.
|
150
|
100
|
|||||
|
Beta Probe
|
Scintillator (11.6 cm2 open and active area) used for
beta detection.
|
75
|
40
|
|||||
|
Low Energy Gamma Probe
|
1"x1mm NaI gamma scintillator probe for low energy
gamma (I-125) and X-ray surveys.
|
75
|
40
|
|||||
|
Pancake G-M Probe
|
Aluminum housed G-M tube (15 cm2 active area) used for
alpha, beta/gamma survey.
|
40
|
30
|
|||||
|
Gamma Probe
|
NaI 2"x2" probe with gamma scintillator used for high
energy gamma surveys. High sensitivity gamma survey when used with polyshield
as collimator.
|
75
|
40
|
|||||
| Ludlum 44-17 | Low Energy Gamma Probe | 2" x 2mm NaI gamma scintialltor probe for low energy gamma (I-125) and X-ray surveys. |
125
|
75
|
||||
|
Gamma Probe
|
NaI 3"x3" probe with gamma scintillator used for high
energy gamma surveys. High sensitivity gamma survey when used with polyshield
as collimator.
|
500
|
300
|
|||||
|
Shielded Pancake G-M Probe
|
Lead shielded G-M tube (15 cm2 active area) used for
alpha, beta-gamma survey. For use in high gamma shine areas.
|
50
|
35
|
|||||
|
Beta Probe
|
Plastic beta scintillator (126 cm2 active area) used
for surface contamination monitoring.
|
95
|
75
|
|||||
| Ludlum 182 | Radon Flask Counter | Lucas Cell Counting |
200
|
100
|
||||
| Ludlum 218 | Radon Flask Counter | Large flask counter (5 in. dia.) Great for gross alpha soil sample counting. Contact Chuck Farr or Ken Baker at ERG for discussion on how to set up a gross alpha field lab using the Model 218. |
350
|
200
|
||||
|
Floor Monitor Cart, Gas Proportional Probe, and Ludlum
2221 or 2360 Detector
|
Gas proportional (582cm2 active area) used for floor /
surface contamination monitoring. Must be charged with P-10 counting gas. The
price includes cart, meter, probe and regulator. User must provide P-10 gas
cylinder.
|
700
|
350
|
|||||
|
Eberline HP210L
|
Shielded Pancake G-M Probe
|
Lead shielded G-M tube (15 cm2 active area) used for
alpha, beta-gamma survey. For use in high gamma shine areas.
|
50
|
35
|
||||
|
Alpha Spectra FIDLER
|
Low Energy Photon Probe
|
Beryllium window thin NaI scintillator
for the detection of low energy photons. (F)ield (I)nstrument for (D)etecting
(L)ow (E)nergy (R)adiation.
|
800
|
300
|
||||
| MIE Personal DataRAM pDR-1000AN | Aerosol Monitor | Hand-Held and fixed-point, real-time aerosol monitor and data logger |
600
|
200
|
||||
| Photovac 2020 PID | Photoionization Detector | The Photovac 2020 PID is
ideal for the fast detection of Volatile Organic Compounds (VOCs). Weighing
under 2 lbs., the Photovac 2020 is light, yet rugged. Samples are drawn in
through the internal pump and results are displayed within seconds on the
large, easy-to-read backlit LCD display. |
600
|
200
|
||||
| LEL, CO, O2 H2S Monitor | Allows you to continuously monitor up to five gases simultaneously in a single compact unit. Weighing only 30 ounces, the Passport Personal Alarm can be hand held, clipped to your belt, or positioned in a stationary area. |
600
|
200
|
|||||
| Extech Model 407330 | Digital Sound Meter | NIST Traceable Digital Noise Meter. 40 to 130dB measuring range. Record Max/Min values over time |
75
|
50
|
||||
|
Lapel Air Sampler
|
For personal air sampling. Sampling rate of up to 3 liters per minute. Includes charger, and 37 mm filter holder. Cyclone particle separator available. |
200
|
120
|
|||||
| MiniBUCK M-5 Primary Flow Lapel Calibrator | NIST traceable digital calibrator for MSA Escort ELF Air Sampler. |
200
|
100
|
|||||
|
Eberline RAS-1
|
Intermediate Volume Air Sampler
|
For air quality measurements. Sampling rate of up to
80 liters per minute. Unit comes with 47 mm filter holder.
|
125
|
100
|
||||
|
37mm Air filter
|
Gelman Type A/E 37mm Glass Fiber Filter. Box of 100.
|
50
|
||||||
|
47mm Air filter
|
Gelman Type A/E 47mm Glass Fiber Filter. Box of 100.
|
50
|
||||||
|
37mm Air filter cartridge
|
Plastic cartridge to hold 37mm air filter. Package of
10.
|
50
|
||||||
|
47mm Planchetts
|
47mm aluminum planchetts. Package of 100.
|
25
|
||||||
| Trimble Pro XRS & TSCe | GPS Survey System | GPS data collection and data maintenance system that provides real-time submeter accuracy. Incorporates a 12-channel, differential correction service antenna, coast guard beacon antenna, and DOD GPS satellite antenna in one housing |
Model 44-10
|
3000
|
750
|
|||
|
FIDLER
|
3400
|
850
|
||||||
| RadMap |
Ultrasonic Automated Survey System
|
Ultrasonic survey system that automatically records ratemeter/scaler output and associated X, Y, Z position. For full description see Radmap System Page. |
3000
|
n/a
|
||||
| GE Energy Model RSS-131 HPIC | High Pressure Ion Chamber | Pressurized Ion Chamber - For precise exposure unit measurementments. Results in milliroentgen/hour (mR/hr). |
2500
|
1000
|
||||
|
Eberline Depleted U
|
Electroplated Source
|
Exempt quantity Depleted Uranium source.
|
50
|
25
|
||||
|
Eberline Th-230
|
Electroplated Source
|
Exempt quantity Thorium-230 Alpha source.
|
50
|
25
|
||||
|
Eberline Sr/Y-90
|
Electroplated Source
|
Exempt quantity Strontium-90 / Yttrium-90 source.
|
50
|
25
|
||||
|
The Source Cs-137
|
Button Source
|
Exempt quantity Cesium-137 source.
|
50
|
25
|
||||
|
The Source Tc-99
|
Electroplated Source
|
Exempt quantity Technetium-99 Beta source.
|
50
|
25
|
||||
|
EG&G Ortec MCA
|
Multi-Channel Analyzer
(Field portable) |
Micro NOMAD or DigiDART field portable gamma-ray MCA with NaI 2"x2" or 3"x3" detector and appropriate EG&G ORTEC software. |
800
|
350
|
||||
|
Polyshield Lead Collimator
|
1/2" thick lead shield used with Ludlum Model 44-10
for high sensitivity gamma survey.
|
50
|
20
|
|||||
| Removable contamination smears | 1 3/4" dia. cloth smears premounted on folders. Box of 250. |
25
|
||||||